Solutions · Commercial plants

We integrate what your process needs

Our commercial projects integrate 11 different decarbonisation technologies, depending on the characteristics of each factory.

Concentrated solar thermalConcentrated solar thermalSteam up to 400 °COur own technologyCST
When it makes sense
It needs available space. It suits processes that need steam, pressurised water or thermal oil at high temperature, in locations with good direct solar radiation.
See the Heineken case →
Flat-plate collectorEvacuated-tube collectorLow-temperature solar thermalProcess hot water with flat-plate and evacuated-tube collectorsFPCETC
When it makes sense
Hot-water processes below about 100 °C, with roof or ground space. It is generally used for preheating.
Heat pumpHeat pumpRecovers waste heatHP
When it makes sense
When there is waste heat that can be recovered, or heating and cooling demands can be combined. Some units reach 180 °C, but most work below 120 °C.
Electric boilerElectric boilerBackup and demand peaks with renewable electricityEB
When it makes sense
There is electrical capacity available or the option to install PV, and the demand profile matches when electricity is available.
Water tankLatent heat storageThermal storageDaytime heat, available at nightDTTLHS
When it makes sense
When renewable production does not match demand and heat is carried in fluids such as pressurised water or thermal oil.
Solid storage with resistive heatingElectrified storage (power2heat)Turns cheap electricity into heat stored at high temperatureEHS
When it makes sense
When electricity is available or there are renewable surpluses, and the aim is a high share of decarbonisation.
PhotovoltaicsPhotovoltaic-thermal (hybrid)PhotovoltaicsRenewable solar electricityPVPVT
When it makes sense
When there is available surface and electric technologies at the plant.
BatteryBatteriesStored electricity for expensive hoursBAT
When it makes sense
When electricity production and demand do not coincide, or to make use of cheap hours.
Along the cost curve

Where each technology fits

We analysed the designs the CCD calculates for real factory cases. Not every technology competes in the same stretch: some give the cheapest heat at the start, others are what make 100% possible.

0–30%Solar solutions

More capital-intensive, but with very low operating costs. How much they can decarbonise is limited by sunshine hours and depends mainly on the space available.

30–70%Partly electrified solutions

They combine solar with storage, heat pumps and electric boilers. Their cost is split between investment and operation (electricity consumed).

70–100%Fully electric solutions with storage

Electric boilers and electrified thermal storage (power2heat) that make it possible to shift heat production.

Decarbonisation cost curve (CCD)illustrativeHover over or tap a technology to see where it appears on the curve.
0 %30 %70 %100 %
ETCEvacuated tubes
BATBatteries
DTTWater tank
FPCFlat-plate collector
CSTConcentrating Fresnel
HPHeat pump
LHSLatent heat
PVPhotovoltaics
EBElectric boiler
EHSPower2heat
% decarbonisation →
Range where it appears (also in combination with other technologies)Where it concentratesTrend observed in cases calculated with the CCD. Every factory has its own curve.
Business model

You bring the heat demand.
We bring the plant.

Heat Purchase Agreement

Buy the heat, not the plant

We design, finance, build and operate the plant at your factory. You pay only for the MWh of heat you use, at a stable price for the whole contract.

  • No upfront investment
  • Heat price known from day one
  • Operation and maintenance included
Turnkey

Or own the plant

If you'd rather own it, we hand over the plant finished and running: engineering, procurement, construction and commissioning.

  • One partner for every technology
  • Design optimised with the CCD
  • Optional maintenance
01We study your siteWith your data, the CCD calculates every option.
02We deliver your decarbonisation cost curveThe optimal design for each level of decarbonisation.
03We buildEngineering, equipment and works, without stopping your process.
04We operate and supply your heatFor the whole contract, with continuous monitoring.
Frequently asked questions

What we are asked most

Cost and contract

How much will the heat cost me?

It depends on your demand, your process temperature, your location and your gas and electricity prices. That is why we don’t quote a generic price: we calculate your decarbonisation cost curve, which gives you the heat price in €/MWh for every decarbonisation level, compared with your gas boiler.

The curve is free and you receive it in under 24 hours.

How we calculate the cost →
Do I have to invest?

Not if you choose to buy the heat: we design, finance, build and operate the plant, and you pay only for the MWh of heat you use, at a stable price for the length of the contract. If you would rather own the plant, we deliver it turnkey.

See the Heineken case →
Are there public grants?

Yes. Depending on the country, there are grants that fund part of the investment, energy-saving certificates (CAEs in Spain, for example) and operating support such as the European Commission’s heat auction. We help you size the project and prepare the application.

Open calls →
What if the detailed study doesn’t confirm the curve?

The curve is free. If you decide to go ahead, the detailed study of the point you choose does have a cost, but if its results do not meet the values on the curve, it costs you nothing.

Implementation

Do I need free space to decarbonise?

Not necessarily. We analyse the space you have available and the CCD only considers the technologies that fit in it. If you have land or roof space, the curve includes solar technologies; if not, they are left out of the simulation.

Do I have to change my process or my boiler?

No. The plant delivers heat into your existing network, as steam, hot water or thermal oil, at your process conditions. Your boiler stays in service as backup and covers whatever the renewable plant doesn’t.

Operation and risk

Who operates and maintains the plant?

If you buy the heat, we do: operation and maintenance are included. The plants run automatically and we supervise them remotely. If you buy the plant turnkey, you decide whether to operate it yourself or contract its maintenance to us.

What if the plant produces less than expected?

When you buy the heat you pay only for the heat you receive, so the production risk is ours. With turnkey, performance and availability guarantees are set in the contract.

Getting started

What data do you need to start?

To build your cost curve we use six groups of data: hourly demand, process, site, electricity, waste heat, and gas and electricity prices.

Request my curve →
What size of factory does it make sense for?

We have built everything from units of a few tens of kW to plants of several MW.

How much do you want to decarbonise?

Tell us about your case and we’ll send you your personalised decarbonisation curve. Every technology, every combination, the best design for each level of decarbonisation.

Get your curve